Products · Refrigeration Systems

Condenser Outdoor Units

Horizontal · Vertical · V-Type · Commercial · NH₃

FCH/FCV · FCW · FCV 3T · Unit · NCH/NCV/NCW

Condenser Outdoor Units

AGA condenser outdoor units, air-cooled units that reject heat outdoors in the refrigeration cycle. Horizontal, vertical, V-type, commercial and ammonia series cover the outdoor-unit need of Split systems; grooved copper or stainless tube and axial fans provide high condensation efficiency.

Grooved copper tube / aluminum fin (stainless tube on NH₃ series); RAL 9016 electrostatic coated casing; Ziehl-Abegg · EBM fans. Refrigerants R404A · R507 · R134A · R407A · R407C · NH₃; capacity range 6.3–2582 kW.

  • Horizontal · vertical · V-type · commercial · ammonia
  • Grooved Cu / AISI 304 tube · Al fin
  • Fin spacing 2,1 · 2,3 · 2,5 · 3,2 mm
  • Ziehl-Abegg · EBM · EC fan option
  • 6,3 – 2582 kW · 1–20 fan
  • FMC AC / EC speed control · adiabatic option
Technical Specifications
Equipment
Advantages
Applications
  • Product typeRoom cooler · condenser outdoor unit
  • SeriesFCH/FCV · FCW · FCV 3T · Condenser unit · NCH/NCV/NCW
  • CoilGrooved Cu / AISI 304 · Al fin
  • FanZiehl-Abegg · EBM · IP44 / IP54
  • CasingAlMg3 / galvanized · RAL 9016
  • Capacity6,3 – 2582 kW
  • RefrigerantR404A · R507 · R134A · R407A · R407C · NH₃
  • Fin spacing2,1 · 2,3 · 2,5 · 3,2 mm
  • DefrostAC · EC · FMC speed control
  • Supply1F / 3F · 50–60 Hz
  • Outdoor installation · support structureYes
  • Partition between fan sectionsYes
  • Lifting lug · mounting feetYes
  • EC fan · FMC speed controlOption
  • Epoxy / Mg-Al / copper finOption
  • Split cold room outdoor unitSuitable
  • Commercial type, small capacitySuitable
  • Industrial high capacitySuitable
  • NH₃ air-cooled condenserSuitable
  • V-type compact layoutSuitable
Why a Condenser?

High Heat Rejection

AGA condenser outdoor units deliver high condensation performance outdoors with horizontal/vertical/V-type construction, EC fans and FMC control.

High Heat Rejection

Efficient condensation with grooved tube and axial fans.

Flexible Construction

Horizontal, vertical and V-type installation options.

Outdoor Durability

RAL 9016 electrostatic coated casing · UV protection.

Wide Capacity

6.3–2582 kW, from commercial duty to industrial NH₃.

EC Fan Option

Ziehl-Abegg · EBM · FMC EC speed control.

Adiabatic Option

Pre-cooling that holds capacity in hot climates.

Condenser Outdoor Units

Condenser outdoor units reject condensation heat to the outside air. AGA FCH/FCV horizontal-vertical, FCW V-type, FCV 3T commercial, condenser units and NCH/NCV/NCW ammonia series fit Split and industrial systems.

System Advantages

Grooved tube with high condensation efficiency.

Partitioned fan sections with reverse rotation is prevented.

1–20 fan with scalable capacity.

Lifting lug and feet with easy installation.

Ziehl-Abegg · EBM high-efficiency fans.

FMC AC/EC with fan speed control.

RAL 9016 casing with corrosion and UV resistance.

Adiabatic cooling option with summer performance.

Configuration Options

Select construction, fan, fin and control options for your project.

Condenser Series

FCH / FCV

  • 11 – 1428 kW
  • Horizontal or vertical mounting
  • Fan Ø500 – 910 · 1–14 fan
  • Universal industrial

FCW — V-Type

  • 78 – 2095 kW
  • V construction
  • Fan Ø800 – 910 · 2–20 fan
  • Compact high capacity

FCV 3T — Commercial

  • 6,3 – 69 kW
  • 1–3 fan · Ø350 – 500
  • Fin 2,3 mm
  • Commercial Split applications

Condenser Unit

  • 16 – 275 kW
  • Commercial / industrial package
  • Horizontal · vertical · V option
  • Outdoor unit ready to install

NCH / NCV / NCW

  • 12 – 2582 kW
  • NH₃ air-cooled
  • Stainless tube · Al fin
  • Horizontal · vertical · V-type

Control Options

  • FMC AC voltage control
  • FMC EC · EC fan
  • Stepped / continuous modulation
  • Adiabatic cooling option

What Are Condenser Outdoor Units?

A condenser outdoor unit is an air-cooled heat exchanger that condenses hot high-pressure gas and rejects the heat outdoors. Axial fans move air across the coil; in Split systems it is the outdoor side of the evaporator / refrigeration package.

The AGA range includes FCH/FCV horizontal-vertical universal, FCW V-type, FCV 3T commercial, condenser units (16–275 kW) and NCH/NCV/NCW ammonia series. Coils use grooved copper tube (or stainless tube for NH₃) and aluminum fins.

Refrigerant options are R404A · R507 · R134A · R407A · R407C and NH₃. Fan supply is 1F / 3F · 50–60 Hz; EC fans and FMC control provide energy-efficient speed control.

FCH FCV air-cooled condenser
FCH · FCV · FCW · 3T

Air-Cooled Condensers

Universal horizontal/vertical (FCH/FCV), V-type (FCW) and commercial (FCV 3T) series are designed for outdoor installation. Arrangements from 1 to 20 fans, grooved copper tube and 2.1–2.5 mm fin spacing provide high condensation capacity.

  • FCH/FCV: 11 – 1428 kW · horizontal/vertical.
  • FCW: 78 – 2095 kW · V-Type.
  • FCV 3T: 6,3 – 69 kW · commercial.
  • Fan: Ziehl-Abegg · EBM · EC option.
Condenser unit
Condenser Unit

Commercial and Industrial Units

Condenser units supply the coil and fan section as a package ready to install. Commercial and industrial models run from 16 to 275 kW with horizontal, vertical or V-type condenser options.

  • Capacity: 16 – 275 kW (R404A).
  • Fin pitch: 2,3 mm · other spacings option.
  • Coating: Epoxy / coated Al fin.
  • Option: EC fan · high-temperature fan.
NH3 ammonia condenser
NCH · NCV · NCW

Ammonia Air-Cooled Condensers

NCH/NCV/NCW series are built for NH₃ applications with stainless tube and aluminum-fin coils. Capacity is 12–2582 kW, with horizontal, vertical and V-type construction.

  • Capacity: 12 – 2582 kW.
  • Tube: Stainless steel · Al fin.
  • Fin pitch: 2,1 · 2,5 · 3,2 mm.
  • Equipment: Lugs · feet · UV switch.

Standard Equipment List

AGA condenser outdoor units are supplied with the following components:

  • Condensing coil with grooved copper or stainless tube
  • Aluminum fin · 2.1 / 2.3 / 2.5 / 3.2 mm pitch
  • Axial fan · Ziehl-Abegg / EBM · 1–20 fans
  • Electrostatic powder-coated galvanized / steel casing · RAL 9016
  • Partition sheet between fan sections
  • Mounting feet · lifting lugs
  • Support structure · outdoor installation
  • Option: EC fan · FMC AC / EC speed control
  • Option: epoxy / Mg-Al / copper fin
  • Option: adiabatic cooling system
  • Option: high-temperature fan/Motor
  • Option: UV-resistant safety switch · cable duct
Fields of Application

Condenser Applications

Outdoor heat rejection for Split cold rooms and commercial, industrial and ammonia systems.

Split Cold Room

Heat rejection as an outdoor unit.

Commercial Applications

Low-to-medium capacity with FCV 3T.

Industrial Plant

High capacity with FCH/FCV and FCW.

V-Type Layout

High kW in a compact footprint.

Condenser Unit

Packaged outdoor unit, ready to install.

NH₃ Systems

NCH/NCV/NCW ammonia condenser.

Hot Climate

Summer performance with the adiabatic option.

Central / Rack

Heat rejection for multi-compressor systems.

Food & Logistics

Cold-chain and warehouse projects.

Technical Data

Condenser Technical Specifications

Standard technical specifications of AGA condenser outdoor units.

Product type Air-cooled condenser outdoor unit
Series FCH/FCV · FCW · FCV 3T · Condenser unit · NCH/NCV/NCW
Cooling / condensation capacity 6,3 – 2582 kW
Refrigerant R404A · R507 · R134A · R407A · R407C · NH₃
Coil Grooved Cu / AISI 304 · Al fin
Fin spacing 2,1 · 2,3 · 2,5 · 3,2 mm
Fan brands Ziehl-Abegg · EBM
Number of fans 1 – 20 (depending on the series)
Control FMC AC · FMC EC · EC fan
Casing Electrostatic coated · RAL 9016
Power supply 1F / 3F · 50–60 Hz
Installation Horizontal · vertical · V-type · outdoor
Option Adiabatic · coated fin · high-temperature fan
Series Capacities

Condenser Capacity Ranges

Catalog capacities are summarized for R404A / the relevant standard conditions.

Series Capacity Refrigerant Construction Fan
FCH / FCV 11 – 1428 kW HFC Horizontal / Vertical 1–14 · Ø500–910
FCW 78 – 2095 kW HFC V-Type 2–20 · Ø800–910
FCV 3T 6,3 – 69 kW HFC Commercial 1–3 · Ø350–500
Condenser Unit 16 – 275 kW HFC Horizontal / Vertical / V Packaged unit
NCH / NCV / NCW 12 – 2582 kW NH₃ Horizontal / Vertical / V 1–14+